Primary Fluid Systems products are certified to a number of standards, including CRN, CE Marking, and NSF/ANSI-61. For more details, please see below.
The following Primary Fluid Systems Inc. products are CRN certified for all of Canada:
TOP VALVE: Back pressure and pressure relief valves
AccuPulse: Pulsation Dampeners
For further information on our CRN approved products, please contact one of our Technical Sales Representatives with your application or inquiry.
For more information on our products, see our Product Engineering Specification Booklet at click here.
A Canadian Registration Number (CRN) for a boiler or pressure vessel is defined by CSA B51 Clause 4.3 as:
consisting of a letter, four digits, and a decimal point followed by up to ten digits and/or two letters
the first letter and four digits are part of a sequential numbering system used by the issuing province or territory
the first digit or letter to the right of the decimal point indicates the province that issued the particular number
the following identifications are used in accordance with the code:
1 - British Columbia
2 - Alberta
3 - Saskatchewan
4 - Manitoba
5 - Ontario
6 - Quebec
7 - New Brunswick
8 - Nova Scotia
9 - Prince Edward Island
0 (zero) - Newfoundland
T - Northwest Territories
Y - Yukon Territory
N - Nunavut
the letter C may follow the designation of first registration if a design is registered in all jurisdictions. No jurisdiction issues the letter C; it is a convenience for stamping once the manufacturer has received all the registrations.
to be eligible for use in Alberta, the CRN must have the digit 2, or the letter C, somewhere after the decimal point.
For selling to and within EU countries, it has become increasingly important to have CE certification and marking. For our industry of metering pump accessories, Pressure Equipment Directive (PED) 97/23/EC is applicable.
The majority of our products are classified as SEP (Sound Engineering Practice). This classification means that our products do not require CE marking or certification in order to be used within the EU.
Product |
Connection Size Range DN (Inches) |
Max. Pressure Rating Bar (PSIG) |
PED Category |
Top Valve |
8 to 50 DN |
25 Bar |
SEP |
PFS Injection Quill |
15 DN |
10 - 207 Bar |
SEP |
PFS Corporation Stop |
15 DN |
10 - 138 Bar |
SEP |
Accu-Vent |
8 DN to 20 DN |
10 - 18 Bar |
SEP |
Accu-Pulse - Some Models & Sizes SEP Conformant. |
For further information on PED 97/23/EC and its relation to our products, please click the following link.
CE Letter of Non-Applicability
Should you have any questions, please contact our technical sales reps.
Primary Fluid Systems Inc. has recently attained certification to the NSF/ANSI-61 standard for a number of products and materials.
As of November 2016, we have CSA Group approval for the following products:
This means that the above products are all certified to NSF/ANSI-61, and appropriate for drinking water use.
Should your project require NSF/ANSI-61 certified products, please do not hesitate to contact one of our technical sales representatives for more information.